Model:H30
Use:Pitot tubes for the measurement of water velocity in open channels and closed ducts. Tubes are stainless steel and mounted on a supporting body with scale.
Tubes are in stainless steel and mounted on a supporting body with scale. They are supplied with a watertight gland for installation below water level.
In order to measure velocity, the Pitot tubes must be connected to a manometer, such as the Armfield H12-8 or H12-9.
When used with the H12-9, the range is 0 – 5.2m/s. When used with the H12-8 the range is 0 – 19.8m/s