    EPC Products Transducer & Data logger Strain Gauge Weldable AWC-8B Quarter bridge with 3-wire method
    产品中心
    AWC-8B Quarter bridge with 3-wire method

    Model:AWC-8B

    Use:Quarter bridge with 3-wire method

    Standard:

    These strain gauges have hermetically sealed construction with the sensing element encapsulated in the stainless steel tube. This construction helps to simplify the coatings for moisture and water proofing, and the strain gauges are suited to strain measurement for long term and/or in harsh environment.

    Main object material Metal
    Operational temperature -20 to +100℃
    Temperature compensation range AWC-8B: +10 to +100℃
    Bonding adhesive Spot welding (TML spot welder W-50R is required)
    Backing SUS304
    Element Special alloy
    Strain limit 0.5% (5000 x 10-6 strain)
    Fatigue life at room temperature 1 x 106 (±1000 x 10-6 strain)