Project Case
Model:AWM-8
Use:The AWM is usable up to 300℃ for both static and dynamic measurement.
The AWM is usable up to 300℃ for both static and dynamic measurement. The backing material is available in Inconel 600 or SUS304 which should be selected according to the test specimen material.
Main object material | Metal |
---|---|
Operational temperature | -196 to +300℃ |
Temperature compensation range | RT to +300℃ |
Bonding adhesive | Spot welding (TML spot welder W-50R is required) |
Backing | Inconel 600, SUS304 |
Element | Special alloy |
Strain limit | 1% (10000 x 10-6 strain) |
Fatigue life at room temperature | 1×106 (±1000×10-6 strain) |