    EPC Products Transducer & Data logger Strain Gauge Strain Gage Related Products Strain Gauge Adhesives
    产品中心
    Strain Gauge Adhesives

    Model:Strain Gauge Adhesives

    Use:adhesive for strain gauges

    Standard:

    Related Products

    CN adhesives(General purpose)

    Single-component adhesive for strain gauges. The time required to bond the gauge is extremely short and handling is very easy. The thin bonding layer allows adhesion to plastic objects as well as metal. Curing time under normal conditions is 20~60 seconds


    CN-E adhesives(Concrete, Mortar)

    Single-component adhesive featuring high viscosity for bonding strain gauges to porous materials such as concrete and mortar. Curing time under normal conditions is 40~120 seconds.


    CN-R adhesives(Fast hardened type for cold district)

    Single-component cement for accelerating cures in lower ambient temperature, or lower relative humidity. Curing time under normal conditions is 10~30 seseconds.


    CN-Y adhesives(Post-yield)

    Single-component adhesive designed exclusively for use on post-yield strain gauge. Offers minimum degradation in bonding performance (peel strength) due to aging. Suitable when a large strain measurement is made after a few days or more of bonding the strain gauge. Curing time under normal conditions is 60~120 seconds.

    P-2 adhesives(General purpose)

    Two-component room-temperature-curing polyester adhesive for bonding PF, P and F series strain gauges. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~6% by weight of drug A. Use the mixed adhesive within 5~15 minutes.

    RP-2 adhesives(Concrete, Mortar)

    Two-component room-temperature-curing polyester adhesive for bonding PF and P series strain gauges. The mixing procedure is the same as above for P-2 adhesive. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~4% by weight of drug A. Use the mixed adhesive within 10~20 minutes.

    PS adhesives(Concrete,Mortar,Wood)

    Two-component room-temperature-curing polyester adhesive. Used as a surface precoating agent for bonding P and PF series gauges to concrete and also as an adhesive for WFLM series gauges. The special filler contained exhibits alkali resistance and effectively shuts off moisture and gas from inside of the concrete. Its high viscosity enables use on vertical walls or ceilings. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~4% by weight of drug A.

    NP-50B adhesives(High temperature)

    Two-component room-temperature-curing polyester adhesive for bonding QF, ZF and BF series strain gauges. Put the necessary quantity of drug A into the supplied mixing vessel then add drug B by drops to total 3~4% by weight of drug A. Use the mixed adhesive within 5~20 minutes.


    C-1 adhesives(Long-term measurement, Transducer-specific)

    Single-component heat-curing type adhesive. For use on strain gauges that are suited to heat curing. Enables reliable measurement for long periods and in high temperature up to 200°C.


    EA-2A adhesives(Cryogenic temperature)

    Two-component room-temperature-curing epoxy ahesive for bonding CF series strain gauges for use in temperature from cryogenic ( - 269 ℃) up to 50 . Mix the necessary quantity of drugs A and B at the weight ratio of 2 to 1.


    EB-2 adhesives(Long-term measurement)

    Two-component room-temperature-curing epoxy adhesive for bonding strain gauges for use in temperatures from -60°C to +150°C. Enables stable measurement for a long period of time. Mix the necessary quantity of drugs A and B at the weight ratio of 10 to 3.


    A-2 adhesives(Bolt embedding)

    Two-component heat-curing epoxy adhesive for bonding BTM strain gauges. Mix the necessary quantity of drugs A and B at the weight ratio of 10 to 1, then pour the mixed adhesive into a hole drilled of the bolt in which the gauge is inserted. Keep at room temperature for 12 hours, then cure at 140°C in furnace for 3 hours.