PF Series Polyester Foil Strain Gauge

Model:PF Series Polyester Foil Strain Gauge

Use:These are foil strain gauges utilizing a polyester resin backing which is the same as the P series.

Standard:

These are foil strain gauges utilizing a polyester resin backing which is the same as the P series. The gauge length is available in 3 ranges of 10, 20 and 30mm, so it is suited mainly to strain measurement on concrete or mortar. The backing is transparent and the installation is easy.

Applicable
specimen
Metal, Concrete, Mortar
Backing
Polyester
Operational
temperature(°C)
-20 ~ +80°C
Element
Cu-Ni
Temperature
compensation range(°C)
+10 ~ +80°C
Strain limit
2%
(20000×10-6 strain)
Applicable adhesive
CN-E, RP-2, PS
Fatigue life
at room temperature
1×106
(±1500×10-6 strain)
 


STEEL, CONCRETE, MORTAR MATERIALS USE

Gauge pattern
Type
Gauge
length
(mm)
Gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
Single-element
(G.F. 2.1 approx.)
PFL-10-11
PFL-10-11 10 0.9 17.5 5 120
PFL-20-11 20 1.2 28.0 6 120
PFL-30-11 30 2.3 40.0 7 120
90°2-element Rosette 
Stacked type
(G.F. 2.1 approx.)
PFLC-3-11
PFLC-20-11 20 1.2 28 28 120
PFLC-30-11 30 2.3 40 40 120
45°/90°3-element Rosette
Stacked type
(G.F. 2.1 approx.)
PFLR-30-11
PFLR-20-11 20 1.2 28 28 120
PFLR-30-11 30 2.3 40 40 120

Single axis / 2-element rosette 0°/90° / 3-element rosette 0°/45°/90°
Each package contains 10 strain gauges.




Dedicated integral leadwire recommended for P series
 

For general use
Application Product name Lead wire code Operating temperature (°C ) Leadwire code exampled
General use (temperature unchanged during measurement) Paralleled vinyl LJB-F -20~ +80 PFL-10-11-3LJB-F
LJC-F PFL-10-11-3LJC-F
General use 3-wire paralleled vinyl LJBT-F -20~ +80 PFL-10-11-3LJBT-F
LJCT-F PFL-10-11-3LJCT-F
1-gauge 4-wire system 0.08mm2 polypropyrene 4-wire paralleled -LQM-F LQM-F -20~ +100 PFL-10-11-3LQM-F
0.08mm2 vinyl 4-wire paralleled leadwire LBQM/LBQM-F LBQM-F -20~ +80 PFL-10-11-3LBQM-F

* Strain gauges of 2-element / 3-element rosette are not available with integral lead wire. 
* Only the leadwires using lead-free solder are available for strain gauges with CE marking.





Standard leadwire integrated strain gauges of PF series (Single-element )

Leadwire used: 0.11mm2 / Total leadwire resistance per meter: 0.32Ω

PFL-10-11-LT

Type
Gauge
length
(mm)
Gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
Lead wire
pre-attached
Type name
of lead wire
preattached
PFL-10-11
10
0.9
17.5 5
120
Paralleled 1m
Paralleled 3m
Paralleled 5m
3-wire 3m
3-wire 5m
-1LJC-F
-3LJC-F
-5LJC-F
-3LJCT-F
-5LJCT-F
PFL-20-11
20
1.2
28.0 6
120
Paralleled 1m
Paralleled 3m
Paralleled 5m
3-wire 3m
3-wire 5m
-1LJC-F
-3LKC-F
-5LJC-F
-3LJCT-F
-5LJCT-F
PFL-30-11
30
2.3
40.0 7
120
Paralleled 1m
Paralleled 3m
Paralleled 5m
3-wire 3m
3-wire 5m
-1LJC-F
-3LJC-F
-5LJC-F
-3LJCT-F
-5LJCT-F

* Minimum order quantity is 10 gauges.