• HJC黄金城

    EPC Products Transducer & Data logger Strain Gauge Concrete Material Use P Series Polyester Wire Strain Gauge
    产品中心
    P Series Polyester Wire Strain Gauge

    Model:P Series Polyester Wire Strain Gauge

    Use:These are wire strain gauges utilizing a polyester resin backing. They are mainly used for surface strain measurement on concrete, mortar or rock.

    Standard:

    These are wire strain gauges utilizing a polyester resin backing. They are mainly used for surface strain measurement on concrete, mortar or rock.

    Applicable
    specimen
    Concrete, Mortar
    Backing
    Polyester
    Operational
    temperature(°C)
    -20 ~ +80°C
    Element
    Cu-Ni (wire)
    Temperature
    compensation range(°C)
    +10 ~ +80°C
    Strain limit
    2%
    (20000×10-6 strain)
    Applicable adhesive
    CN-E, RP-2, PS
    Fatigue life
    at room temperature
    1×105
    (±1000×10-6 strain)
     



    CONCRETE, MORTAR, ROCK MATERIALS USE

    Gauge pattern
    Type
    Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance
    (Ω)
    Single-element
    (G.F. 2.1 approx.)
    PL-60-11
    PL-60-11 60 1 74 8 120
    PL-90-11 90 1 105 8 120
    PL-120-11 120 1 135 8 120
    90° 2-element Cross
    Stacked type
    (G.F. 2.1 approx.)
    PLC-60-11
    PLC-60-11 60 1 74 74 120
    45°/90° 3-element Rosette
    Stacked type
    (G.F. 2.1 approx.)
    PLR-60-11
    PLR-60-11 60 1 74 74 120

    Each package contains 10 gauges.



    Dedicated integral leadwire recommended for P series
     

    Recommendable integral leadwire for P/PF series with single element.
    No integral leadwire is available for rosette element PLC, PLR, PFLC and PFLR.

    For general use
    Application
    Product name
    Lead wire code
    Operating temperature
    (°C )
    Leadwire code exampled
    General use (temperature unchanged during measurement) Paralleled vinyl LJB-F -20~ +80 PL-60-11-3LJB-F
    LJC-F PL-60-11-3LJC-F
    General use 3-wire paralleled vinyl LJBT-F -20~ +80 PL-60-11-3LJBT-F
    LJCT-F PL-60-11-3LJCT-F
    1-gauge 4-wire system 0.08mm2 polypropyrene 4-wire paralleled -LQM-F LQM-F -20~ +100 PL-60-11-3LQM-F
    0.08mm2 vinyl 4-wire paralleled leadwire LBQM/LBQM-F LBQM-F -20~ +80 PL-60-11-3LBQM-F

    * Strain gauges of 2-element / 3-element rosette are not available with integral lead wire. 
    * Only the leadwires using lead-free solder are available for strain gauges with CE marking.




    Standard leadwire integrated strain gauges of P series


    Leadwire used: 0.11mm2/ Total leadwire resistance per meter: 0.32Ω

    PL-60-11-LT

    Type
    Gauge
    length
    (mm)
    Gauge
    width
    (mm)
    Backing
    length
    (mm)
    Backing
    width
    (mm)
    Resistance
    (Ω)
    Lead wire
    pre-attached
    Type name
    of lead wire
    preattached
    PL-60-11
    60
    1
    74 8
    120
    Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F
    PL-90-11
    90
    1
    105 8
    120
    Paralleled 1m
    Paralleled 3m
    Paralleled 5m
    3-wire 3m
    3-wire 5m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F

    * Minimum order quantity is 10 gauges.
    * PL-120-11 is also available with integral leadwire.
    * 2-element/3-element rosette strain gauges are not available with integral leadwire.

    Project Case
    Solution
    Download
    相关标签
    TML,Tokyo Measuring Instruments Laboratory
    HJC黄金城





      HJC黄金城