Model:PDA-8G
Use:Conforms ASTM D4945 Standards. High strain dynamic load testing and pile driving monitoring system. Performs dynamic load testing on most types of deep foundations.
Standard:JGJ 106-2014, JTJ 254-1998, TB10218-2019, JTG/T 5312-2020, DBJ/T15-60-2019, JG/T 518-2017, ASTM D4945-17
Pile Driving Analyzer® (PDA) System
High strain dynamic load testing and pile driving monitoring system. Perform dynamic load testing on most types of deep foundations.
Calculate bearing capacity and assess structural integrity
Assess driving stresses and hammer performance
Available in cabled or wireless versions
Complete with CAPWAP®, GRLWEAP, and iCAP® software, as well as PDIPLOT to summarize results.
The Pile Driving Analyzer (PDA) system is the most widely employed system for Dynamic Load Testing and Pile Driving Monitoring in the world. High Strain Dynamic Load Tests, also called PDA tests, assess the capacity of several piles in a single day. Pile Driving Analyzer systems also evalsuate shaft integrity, driving stresses, and hammer energy when monitoring installation. If you plan to use your PDA to test non-driven piles make sure to read about that application as well.
The PDA Model 8G is the culmination of a complete redesign effort that incorporates the latest technological innovations and truly embodies Pile Dynamics’s commitment to quality.
The PDA-8G looks complicated, and so does the software that drives it. Thin and ergonomic, it has touch screen gesture control functions such as swipe and two-finger zoom.
The PDA-8G offers up to 16 universal channels of data acquisition, all capable of reading data from Smart Sensors in traditional (cabled) or wireless mode. This functionality allows for extreme pile testing flexibility. Improved data transfer makes it easier to test hydraulic hammers with high blow rates.
PDA tests are performed during driving on pilot or production piles, taking advantage of the high strain impact provided by the driving hammer. Re-strike PDA tests are often recommended; if the driving hammer is no longer on locations, a drop weight may be used to impact the pile.
The PDA-8G takes data obtained by ”accelerometers and strain transducers” easily attached to the pile and calculates foundation capacity. In addition, it calculates multiple important quantities by the Case Method and ”iCAP”®. iCAP computes capacity in real time after every blow by signal matching (similar to CAPWAP®). This calculation is often more accurate than Case Method capacity and better evalsuates stresses in the pile.
With the PDA-8G, the engineer has the option of being in the field for the pile driving test or of using SiteLink® technology. SiteLink technology transmits PDA test data via Internet to an engineer located elsewhere who follows the test in real time. Test data displays and results are identical in both modes.
Technical Specification
Physical
Size: 320 X 250 X 68 mm (12.6 x 9.8 x 2.7 inches)
Weight: 5 Kg (11 lbs.)
Temperature range: 0 to 40°C (32 to 104° F) operating; -20 to 65°C (-4 to 149° F) storage
Display: 26.4cm (10.4”), sunlight readable, resolution 1024 X 768
Built in capacitive touch screen
Video Outputs: HDMI
Power: 4-hour continuous data collection battery pack, 12 VDC car battery, or 100-240 VAC. Extra battery pack supplied.
Charging time: 6-hour maximum
Electronic
Microsoft Windows® 10 Operating System
128 GB SSD internal drive
Ethernet port
4 USB ports
Analog signal conditioning filtering (frequency response) 2.5 KHZ (-3 dB)
16-bit A/D converter with sampling frequency of 10.24 MHz
8 channels with effective digitizing frequency of 10 KHz to 40 KHz selectable
1K, 2K, or 4K data record sizes available
Basic unit accuracy 2%
Functional
Built in calibration test function
Compatible with Smart Sensors
Wireless range up to 100 m (328 ft)
Up to 16 universal (strain or acceleration, piezoelectric or piezoresistive) channels of wireless data acquisition1
Up to 8 universal (strain or acceleration, piezoelectric or piezoresistive) channels of traditional data acquisition
Automatic balancing of signals and signal conditioning
Digital (software) integration of acceleration
Signal conditioning for force and acceleration have similar frequency response
Internal calibration check of strain and acceleration
Signal amplification capability
Triggers on any attached strain transducer
User adjustable pre-trigger buffer size
High speed internet data transmission using SiteLink® through broadband phones or other network device (additional desktop sharing software needed)
Dial up data transmission through data capable mobiles phones connected via USB
1 limited to one piezoelectric accelerometer per box
Other
Operates in English, SI, or Metric units
Includes external USB keyboard, mouse, and WiFi (802.11 b,g,n)
Includes both soft side carry-on luggage case and hard transit case
Equipped for remote technical support using SiteLink®
Available TeamViewer desktop sharing software license for use with SiteLink®
Furnished with licenses for PDA Software Suite (PDA-S, iCAP®, PDIPLOT and PDI Curves), GRLWEAP and CAPWAP®
Full one-year warranty
Technical manual provided in PDF form on a USB drive